正确选择接地点,完善接地系统。良好的接地是保证PLC可靠工作的重要条件,可以避免偶然发生的电压冲击危害。接地的目的通常有两个,其一为了安全,其二是为了抑制干扰。接地系统是PLC控制系统抗电磁干扰的重要措施之一。在PLC控制系统中,具有多种形式的'接地',主要有:
(1)信号地。输入端信号元件的地;(2)交流地。交流供电电源的N线;(3)屏蔽地。为防止静电和磁场感应而设置的外壳或金属丝网,通过专门的铜导线将其接入地下;(4)保护地。将机器设备的外壳或设备内独立器件的外壳接地,用于保护人身安全和防止设备漏电。
为了抑制附加在电源及输入、输出端的干扰,应对PLC系统进行良好的接地。一般情况下,接地方式与信号频率有关,当频率低于1MHz时,可用一点接地;高于10MHz时,采用多点接地;在1~10MH之间时,通常情况下,PLC控制系统采用一点接地,将所有地线端子和相近接地点相连接,以获得抗干扰能力。接地线截面积不能小于2mm2,接地电阻不能大于100Ω,智能信号隔离器,接地线使用地线。
变频器干扰的抑制。
(1)加隔离变压器,信号隔离器,主要是针对来自电源的传导干扰,可以将绝大部分的传导干扰阻隔在隔离变压器之前。
(2)使用滤波器,信号隔离器故障,滤波器具有较强的抗干扰能力,还具有防止将设备本身的干扰传导给电源,有些还兼有尖峰电压吸收功能。
(3)使用输出电抗器,在变频器到电动机之间增加交流电抗器主要是减少变频器输出在能量传输过程中线路产生电磁辐射,影响其它设备正常。